Resource Configuration

59.6.2.209 LGA 100 resource editor

The information displayed in the first part is merely descriptive and shows previously assigned data:

Code: The path of the resource that you are editing is displayed
Type: Shows the resource type
Number: Indicates the ordinal number that identifies that resource in case others of the same type coexist.

The user must enter the following information:
•Name description of the resource you are editing.
•Driver, fixed for the machine type: SAVLGA100.
•Configuration
✓ The logo generator is configured as follows: Indicate how you want the logo to be configured.
Indicate the associated DSK: Indicate if the DSK is internal (INSIDE) or if one of those in the resources (previously configured) must be associated.
(Warning: you need to configure DSKs first because only installed DSKs are displayed)
Preset/Take Mode: Some devices can pre-load the logo before sending it ON AIR in such a way as to speed up the operation at the moment of the take. This possibility can be exploited using preset/take mode instead of standard mode. The preset/take mode is suggested only if a commutation is used for each event. Otherwise, the results could be unpredictable.
NOTICE: the SAV address is the default one, which is 30H.

Serial connection wire: SMPTE 207 (SONY standard)
LGA 100 resource editor - User
After indicating which user and which software the resource has to be installed for, you have to set other data:
•Com no. Indicate the PC com number the machine is connected to.
•Com configuration:
 The com is fixed with the following parameters (the default ones for SAV):
✓Baud: 38400
✓Parity: Odd
✓Stop bits: 1
✓Data bits: 8
422
✓Device (out)- Indicate the no. of the device to be installed when you open the resource.(-1=not installed)
✓Controller (in)- Indicate the no. of the controller to be installed when you open the resource.(-1=not installed)
(Only in the special case where you have a centralized video router which allows you also to commute serial ports, set the data referred to above to 422)

LGA 100 resource editor - User
After indicating which user and which software the resource has to be installed for, you have to set other data:

•Com no. Indicate the PC com number the machine is connected to.
•Com configuration:
 The com is fixed with the following parameters (the default ones for SAV):
✓Baud: 38400
✓Parity: Odd
✓Stop bits: 1
✓Data bits: 8

422
✓Device (out)- Indicate the no. of the device to be installed when you open the resource.
(-1=not installed)

✓Controller (in)- Indicate the no. of the controller to be installed when you open the resource.(-1=not installed)
(Only in the special case where you have a centralized video router which allows you also to commute serial ports, set the data referred to above to 422)