Resource Configuration

59.6.2.254 Sony - DFS-700 resource editor

The first part is merely descriptive and shows data previously assigned:

•Code: The path of the resource you are editing is displayed
•Type: Shows the resource type
•Number: Indicates the ordinal number that identifies that resource in case others of the same type coexist. The user must enter the following information:
•Name: Description of the resource you are editing.
•Driver: Fixed for the machine type: DFS700
•Transaction speed: (Slow, Medium, Fast, Show time in milliseconds for three transaction speeds.)
Number of channels: Specify how many input channels there are; the output channel is one. This information is used to edit the channels in the Main
Notice: By creating this resource, a DSK resource connected to the Master Control will also be automatically created, a resource that must be configured opportunely.
Serial connection wire: SMPTE 207 (wire SONY).

DFS-700 Resource Editor - User 

After indicating to which user and to which program the resource should be activated, it is necessary to set other data:

Com Port Setting

The machine can be controlled directly with a serial wire; in this case, you need to set the n. of com or through UDP by using the ETERESARVAJI software; in this case, you need to show the IP address of the PC where EtereSarvaji runs and the Local Port, always used by EtereSarvaji.

Com configuration

Com data are fixed: 38400, O,8,1

422

Device (out) - Indicate n. of the device which should be activated when the resource is opened. (-1=not managed)
Controller (in) - Indicate the n. of the controller, which should be activated when the resource is opened. (-1=not managed)
(Only in the particular case where you have a centralized video router which allows you also to commute serial ports, set the data referred to above to 422)