Resource Configuration

59.6.2.300 Elpro - Savis-204 / 316 resuorce editor

The information displayed in the first part is merely descriptive and shows previously assigned data:

•Code: The path of the resource that you are editing is displayed
•Type: Shows the resource type
•Number: Indicates the ordinal number that identifies that resource in case others of the same type coexist.
The user must enter the following information:
•Name: Description of the resource you are editing.
•Driver: Choose the relevant driver for the router you have. (The EtereSW driver is not used any longer, and it has been kept only for a matter of compatibility with past installations)
•Model: Choose a model among the available ones.
If the model is not included in the list, choose GENERIC and indicate the number of Inputs and Outputs of your model (this is the only case in which you have to set these parameters).
•Channel's number: Insert the number of the router's inputs and outputs.
•Router switching levels: Some routers allow you to determine the switching levels, that is, to define what has to be switched (Audio only, Audio and Video, Video only, serial port, etc.). If your router offers this option, levels can be set here. In Etere, you have three kinds of switching: AUDIO/VIDEO, SERIAL PORT, and TIMECODE and for each, you can determine the levels to be installed. 

For example, if, on your router, Video corresponds to level 1 and Audio corresponds to level 2, you must activate levels 1 and 2 in the AUDIO/VIDEO box.

If the switching of a possible serial port corresponds to level 4, activate level 4 on the SERIAL PORT box
(if your router does not offer this possibility, leave all levels installed)

Serial connection wire for SAVIS-204:

PC side (RS-232)                SAVIS side
DB9F                        DB9
2 Rx ----------------------------        Tx 1
3 Tx ----------------------------         Rx 2
5 GND -------------------------         GND 3

Serial connection wire for SAVIS-316

PC side                                   Router side
DB9F                                          DB9F
2 Rx ---------------------------        Tx 3
3 Tx ----------------------------         Rx 2
5 GND ------------------------         GND 5

Savis-204 / 316 Resource Editor - User

After indicating which user and which software the resource has to be installed for, you have to set other data:

Com Port Setting:

The video router can be controlled directly through a serial connection (in this case, you have to set the com number) or through UDP with the ETERESARVAJI software (in this case, you have to indicate the IP address of the PC that EtereSarvaji runs in and the Local Port that EtereSarvaji uses.

Com Configuration:

The Baudrate can only be set (default value 4800); other parameters are fixed.
❑Baud: 4800
❑Parity: None
❑Stop bits: 1
❑Data bits: 8

Backup Router

If you wish to manage another router as the Backup router, activate this option, insert com data, or leave the option blank.

The backup router must be completely THE SAME as the main one.