How it Works

92.2.2.2 Configuring Jumpers

The EA1791 Redundancy Switch allows to activate/deactivate some of the available switching modes to use only one or both of them:
•Switch via GPI Mode-A and GPI Mode-B: To be enabled, the jumper JP2 has to be closed inside the device.
•Switch via GPI-to-Device: To activate this mode, both jumpers JP1a and JP1b have to be closed inside the device.

Default_Position 
 
Default Position (GPI-to-Device is disabled)
In the image below it is illustrated the default position of jumpers inside the device, the jumpers JP1a and JP1b are open whereas the JP2 is closed:
Enabling ALL Switching Modes
All switching modes can be used at the same time by closing all Jumpers (i.e. JP1a, JP1b and JP2); in this case, all modes will coexist without any kind of priority (i.e. the latest switch will change the status of the previous one).

Default_Position